August 19th, 1991

NHTSA Campaign Number: 91E030000
Manufacturer: KEYSTONE, INC.
Manufactured Begin Date: January 1st, 1987
Manufactured End Date: January 1st, 1991
Date of Owner Notification: August 1st, 1991

Defect Summary:
THE MATERIAL USED IN THE PAWL AND SHAFT OF THE TWO TOP LOCKING MECHANISMS IN CONTAINER CLIP-ON DIESEL SETS DOES NOT HAVE ADEQUATE TENSILE STRENGTH OR WAS NOT PROPERLY HEAT TREATED, AND COULD CAUSE THE PAWL AND SHAFT TO FRACTURE.

Consequence Summary:
FRACTURE OF SHAFT WHILE GENERATOR IS IN USE MAY CAUSEFLYING DEBRIS AND RESULT IN INJURY TO ANYONE IN VICINITY.

Corrective Summary:
REPLACE THE CAST IRON SHAFTS WITH FORGED STEEL SHAFTS.

Recall Notes:
SYSTEM: GENERATOR.EQUIPMENT DESCRIPTION: 15 KW DIESEL GENERATOR; MODELS; M9, M9A, M9B, M10, M10A,M19, M19A AND M19B USED IN TRANSPORT TAILERS TO POWER REFRIGERATION UNITS.