2015 Horton Ambulance 603 Recalls

All 2015 Horton Ambulance 603 recalls can be found below. It is important to us to provide a complete resource for recall information, so if you know of any additional related recalls, please contact us to let us know.

August 26th, 2016

NHTSA Campaign Number: 16V625000
Manufacturer: Halcore Group, Inc.
Manufactured Begin Date: November 29th, 2013
Manufactured End Date: March 1st, 2016

Defect Summary:
Halcore Group, Inc. (Halcore) is recalling certain model year 2013-2016 Horton ambulances, models 453, 457, 503, 553, 603, and 623, manufactured November 29, 2013, to March 1, 2016. The affected vehicles may have an improperly sealed Cool-Tech air-conditioning condenser controller wire harness that can allow water to enter the controller housing.

Consequence Summary:
If water gets into the controller housing, the controller may short circuit, increasing the risk of an electrical fire.

Corrective Summary:
Halcore will notify owners, and dealers will replace the Cool-Tech condenser fan controller assembly, free of charge. The recall is expected to begin in September 2016. Owners may contact Horton customer service at 1-614-317-9856, or by email at [email protected]

Recall Notes:
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.

December 9th, 2015

NHTSA Campaign Number: 15V828000
Manufacturer: Halcore Group, Inc.
Manufactured Begin Date: October 1st, 2015
Manufactured End Date: November 16th, 2015
Date of Owner Notification: January 4th, 2016

Defect Summary:
Halcore Group, Inc. (Halcore) is recalling certain model year 2015 Horton 623, 603, 503, 553 and 453 ambulances manufactured October 1, 2015, to November 16, 2015 and equipped with the i4G system for controlling the ambulance body electrics. Due to a circuit board component being installed incorrectly, the ambulance body may have electrical system failure of the interior and exterior lights, as well as other life saving electrical equipment such as the oxygen system.

Consequence Summary:
Failure of ambulance body electrics can hinder emergency response and/or rescue efforts, increasing the risk of injury to ambulance patients.

Corrective Summary:
Halcore will notify owners, and Horton will replace the affected electrical component, free of charge. The recall began on January 4, 2016. Owners may contact Horton customer service at 1-800-282-5113.

Recall Notes:
Owners may also contact the National Highway Traffic Safety Administration Vehicle Safety Hotline at 1-888-327-4236 (TTY 1-800-424-9153), or go to www.safercar.gov.