2005 Gillig 35 And 40 Foot Low Floor Recalls

All 2005 Gillig 35 And 40 Foot Low Floor recalls can be found below. It is important to us to provide a complete resource for recall information, so if you know of any additional related recalls, please contact us to let us know.

June 10th, 2005

NHTSA Campaign Number: 05V271000
Manufacturer: Gillig LLC
Manufactured Begin Date: January 1st, 2004
Manufactured End Date: April 11th, 2005
Date of Owner Notification: June 17th, 2005

Defect Summary:
ON CERTAIN TRANSIT BUSES, THE CAST CLAMP PORTION OF THE TORQUE ROD COULD CRACK UNDER INITIAL TORQUEING OF THE CLAMP FASTENERS RESULTING IN BREAKAGE OR CRACKS. CASTING POROSITY AND INCORRECT HEAT TREATMENT CAUSED POTENTIAL WEAKNESS IN THE CAST CLAMP PORTION OF THE TORQUE ROD.

Consequence Summary:
THIS COULD RESULT IN LOSS OF VEHICLE CONTROL AND A CRASH COULD OCCUR WITHOUT PRIOR WARNING.

Corrective Summary:
DEALERS WILL REPLACE THE CAST IRON TORQUE ROD CLAMPS WITH A FABRICATED STEEL CLAMPS FREE OF CHARGE. THE RECALL BEGAN ON JUNE 17, 2005. OWNERS MAY CONTACT GILLIG AT 510-785-1500.

Recall Notes:
CUSTOMERS MAY ALSO CONTACT THE NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION'S VEHICLE SAFETY HOTLINE AT 1-888-327-4236 (TTY 1-800-424-9153), OR GO TO HTTP://WWW.SAFERCAR.GOV.

Recall Comments

No comments have been posted.